Grouped Mice Metabolic Cage Parts

Regular price $30.42
Regular price Sale price $30.42
Sale Contact Us
Product Information Product code : 3700M024

Ensure the continued performance and longevity of your Tecniplast Single Mouse Metabolic Cage with genuine spare parts designed specifically for this system. Whether you're performing routine maintenance, repairing wear and tear, or customizing your setup for specific research needs, having access to replacement components is essential. These spare parts are manufactured to the same high standards as the original cage, ensuring compatibility, precision, and reliability. From collection funnels and urine separation devices to stainless steel hardware and cage inserts, every part supports seamless integration and function. Stocking spare parts helps reduce downtime and maintain the accuracy of metabolic data collection.

The Tecniplast Grouped Mice Metabolic Cage is engineered to enable accurate metabolic monitoring of multiple mice housed together, making it ideal for studies that require social housing conditions. This system allows researchers to measure group-level data on food and water intake, feces and urine output, and other metabolic parameters without compromising animal welfare and while supporting a reliable sample collection in a shared environment. When paired with genuine spare parts, the system maintains its high performance and ensures uninterrupted research continuity.

Choose distributor
  • Specifications

  • Features

  • Brochure

Type Length (inches) Width (inches) Height (inches) Floor Area Chamber Volume
Single Mouse 12.5 10 14.5 31 in² 159 in³
Grouped Mice 12.5 12 13 51 in² 281 in³
Rats < 150 g 12.5 12 13 51 in² 281 in³
Rats between 150 g and 300 g 12.5 12 13 51 in² 281 in³
Rats > 300 g 12.5 12 13 51 in² 525 in³

Features

  • Designed for accurate metabolic and behavioral data collection in rodent research.

  • Supports precise monitoring of urine and feces output for metabolic analysis.

  • Available for mice and rats, with species-specific configurations.

  • Offered with a variety of rack options, including models with preinstalled collection chillers for optimized sample preservation.

  • Constructed with high-quality, autoclavable materials for easy cleaning and sterilization.

  • Engineered with animal comfort and welfare to reduce animal stress.

  • Facilitates long-term metabolic studies with reliable separation of excreta.

  • Leak-proof design to ensure precise sample collection and contamination control.

  • Compliant with international animal research guidelines.

  • Configurable to support single animals or grouped species, depending on study requirements.

Tecniplast Analysis Brochure

Metabolic Cage Manual

Metabolic Cleaning Guide

E-Chiller Product Specifications

E-Chiller

The Tecniplast E-Chiller is an electronic chilling device engineered for metabolic research that fits any Tecniplast metabolic cage (from single-mouse up to rats) to preserve collected urine and feces by maintaining a constant low temperature and slowing enzymatic degradation. Electronically controlled with fine, tight regulation and a settable temperature range of 4 °C to 20 °C, the E-Chiller prevents unwanted fluctuations that can introduce variability in metabolic experiments. Its plug-and-play design and intuitive soft-button display make temperature and time settings immediate and user-friendly, removing the need to pre-freeze chillers in refrigerators and reducing operational complexity, space needs, and costs. Ideal for labs that require reliable sample conservation and reproducible metabolic data, the E-Chiller integrates seamlessly with Tecniplast metabolic systems to support consistent, high-quality experimental outcomes.

Frequently Asked Questions

Have questions? We’re here to help!

Are there any special cleaning requirements for the metabolic caging? 

All components of the metabolic cage are compatible with standard facility-approved cleaning methods, both by hand and machine, except for the PMP-coated parts: the Separating Cone, Urine Funnel, and Urine Ring. These items require delicate handling—avoid contact with bare hands and do not use abrasive or corrosive materials. We recommend hand washing these components with a microfiber cloth, rinsing thoroughly, and then applying your facility-approved disinfectant spray.

Should you use a special diet when performing metabolic studies?

Our metabolic cages are specifically designed for use with powdered diets. This ensures accurate monitoring of food consumption and prevents sample contamination from large food particles that animals might carry into the collection area. Both major diet providers—Teklad and Purina—offer all their diets in powdered form, available in quantities as small as 2 kg. Alternatively, you may grind your standard diet in-house to achieve a
fine powder consistency prior to use.

Is there a way to keep the samples cold during the collection process?


We offer two effective solutions for keeping samples cool during metabolic cage collection: the Chiller and the E-Chiller. The Chiller system features a freezable core housed in a Styrofoam shell, positioned beneath the metabolic cage to passively maintain low temperatures—ideal for general cooling needs without precise temperature requirements. For research applications demanding accurate thermal regulation, the E-Chiller offers electronically controlled cooling, allowing users to set and maintain specific temperatures throughout the collection period. Both systems are compatible with all Tecniplast metabolic cages, except the 3600M021 single mouse model, making them versatile options for most setups.

Do you provide replacement parts for the metabolic caging? 

Yes, every individual component of the metabolic cage can be purchased individually.  Please visit our parts section of the website or contact us at sales@tecniplastusa.com for additional information.

How do you select the properly sized metabolic caging? 

Below is a general overview of the available cages and their key characteristics:

  • 3600M021- Single Mouse Metabolic Cage: Designed for individual mouse collection. Note: Not compatible with Chiller or E-Chiller systems.
  • 3700M022- Group Mouse Metabolic Cage: Accommodates multiple mice simultaneously but can also be used for single mouse collection.
  • 3700M061- Single Rat Metabolic Cage (up to 150g): Includes a conversion kit that allows for both mouse and rat collection, ideal if your study involves the need for flexibility between multiple species.
  • 3700M071- Single Rat Metabolic Cage (150g–300g): Also includes the same conversion kit for mouse/rat flexibility.
  • 3700M081- Single Rat Metabolic Cage (300g+): Designed for larger rats. Note: This cage does not support conversion for mouse use.

Do you have instructions for assembling the metabolic caging?

Yes, please reference the videos below to watch the assembly video for our three different metabolic cages.

Do I need a specialized rack to use metabolic caging?

A dedicated metabolic rack is not required to use our caging system.

  • The 3600M021 metabolic cage includes a built-in stand, allowing it to be placed directly on a benchtop. However, if benchtop space is limited, it can also be used with the metabolic rack. In this case, only a support plate specific to the 3600M021 needs to be purchased separately.
  • The 3700M022, 3700M061, 3700M071, and 3700M081 cages all require either a separate support stand (for benchtop use) or use on the metabolic rack. No additional support plate is needed for these models, as each comes equipped with its own.

The metabolic rack itself is universal and compatible with all five cage models offered.  

Is there any specific guidance we should be concerned about when using metabolic caging? 

The primary consideration is the delicate nature of the PMP-coated components—the Separating Cone, Urine Funnel, and Urine Ring. Even with proper handling and care, these parts are considered consumables due to wear from regular use. We recommend replacing them annually, or less frequently if usage is minimal.

How to Assemble the 3600M021 Metabolic Cage

How to Assemble the 3700M022, 3700M061, and 3700M071 Metabolic Cages

How to Assemble the 3700M081 Metabolic Cage